Compliance Update: May 2026
While the logic of fire safety remains constant, the technical references have evolved. This article has been updated to reflect the transition from NCC 2019 to the current NCC 2022 and the NCC 2025 Preview standards.
Looking for verified fire data? Explore our Fire Hazard Properties & Compliance Page
We have come across confusion in the marketplace about these terms. In some sense, this is understandable, as we often use the abbreviation ‘FR’. It is important to understand that fire rating and fire retardancy are two quite different things, and they have very specific meanings.
When we talk about ‘FR’ at SUPAWOOD, we are typically using the term in relation to Fire Retardancy, which relates to fire hazard properties of materials, in other words how a fire-retardant acoustic panel resists the spread of flames, and how the materials within a space, keep that space safe by preventing the fire from spreading. The relevant NCC portion that applies is the NCC 2022 Specification 7 (formerly Spec C1.10) and Clause C2D11. The performance of wall and ceiling linings is measured using a group number.
Fire Rating or Fire Resistance Level (FRL) is used when buildings need segmentation, to prevent fire spreading from one building to another, or from one section of the building to another.
This is a measurement of a reliable fire-retardant wall system as a whole, for example, this is where a concrete wall is used, or multiple layers of fire retardant plasterboard, or special fire doors. This Fire Resistance Level (FRL) is measured in terms of minutes or hours of how long these products can resist the fire e.g. 60/60/60
At-a-Glance: Fire Retardancy vs. Fire Resistance Level (FRL)
A quick technical comparison of how fire performance is categorized and measured for building materials under the NCC.
| Feature | Fire Retardancy (Group Ratings) | Fire Resistance (FRL) |
|---|---|---|
| Primary Goal | Controls the spread of fire across a surface. | Maintains structural integrity to stop fire transfer. |
| How it's measured | Group Numbers (1, 2, or 3) | Minutes (e.g., 60/60/60) |
| Typical Application | Internal wall and ceiling linings. | Concrete walls, floors, and fire doors. |
| NCC Reference | NCC 2022 Specification 7 | NCC 2022 Specification 1 |
To clear confusion, SUPAWOOD products are fire retardant and designed to achieve specific performance in relation to the NCC 2022 Group Numbers.
Need help determining if you need a Group Rating or an FRL?
Don’t guess on compliance. Work through your project requirements with our technical team.
Wildlife Retreat, Taronga Zoo, Sydney NSW
To read more about SUPAWOOD fire compliance, explore our fire hazard properties page.
For guidance on selecting the correct Fire Group for your project